Acta Univ. Palacki. Olomuc., Gymn. 2008 38(2): 55-64
Validity and reliability of "step count" function of the ActiTrainer Activity Monitor under controlled conditions
- Faculty of Physical Culture, Palacky University, Olomouc
When assessing human physical activity, numerous objective measuring devices, such as accelerometers, pedometers, heart rate monitors, etc. are involved. The ActiTrainer is a new multifunctional monitoring tool putting all these functions together. The main purpose of this study was to realize standardizing measures of the pedometer ("step count") function of the ActiTrainer under controlled conditions of walking and running and to contribute to the verification of the potentials of this device for physical activity assessment. Performance of the ActiTrainer as a step counter was evaluated against the actual number of steps taken during those two stages of locomotion. Reliability was estimated by: 1) comparison of two ActiTrainer units worn simultaneously on the right and left hip, and 2) comparison of the ActiTrainer with the previously verified Yamax Digiwalker SW-700 pedometer. The sample consisted of 20 volunteer subjects. All subjects covered a distance of 1 kilometer on the hard surface of a 400 meter long athletic oval in two stages (walking and running), while keeping a prescribed pace of locomotion. Each subject wore four devices (one ActiTrainer and Yamax unit on the right and on the left hip). When detecting steps under given controlled conditions, accuracy of the ActiTrainer was very high. Values of Pearson's r expressing the relationship between actual and device measured steps ranged from 0.96 to 0.97. Marginal counts of steps measured by ActiTrainer did not exceed a difference of 0.3% from the actual steps taken. Also inter-instrumental (right vs. the left side) and equivalence (ActiTrainer vs. Yamax) correlations were favorably strong. As a step counter, the ActiTrainer seems to be a promisingly accurate monitoring tool.
Keywords: Physical activity monitoring, walking, running, pedometer, accuracy
Prepublished online: January 31, 2009; Published: March 1, 2008 Show citation
References
- Ainswor th, B. E., Bassett, D. R., Strath, S. J., Swartz, A. M., O'Brien, W. L., Thompson, R. W., Jones, D. A., Macera, C. A., & Kimsey, C. D. (2000). Comparison of three methods for measuring the time spent in physical activity. Medicine & Science in Sports & Exercise, 32(9, Suppl.), 457-464.
Go to original source... - Ainsworth, B. E., Haskell, W. L., Whitt, M. C., Irwin, M. L., Swar tz, A. M., Strath, S. J., O'Brien, W. L., Bassett, D. R., Schmitz, K. H., Emplaincourt, P. O., Jacobs, D. R., & Leon, A. S. (2000). Compendium of physical activities: An update of activity codes and MET intensities. Medicine & Science in Sports & Exercise, 32(9, Suppl.), 498-516.
Go to original source... - Bassett, D. R. (2000). Validity and reliability issues in objective monitoring of physical activity. Research Quarterly for Exercise and Sport, 71(2), 30-36.
Go to original source...
Go to PubMed... - Bassett, D. R., Ainsworth, B. E., Swartz, A. M., Strath, S. J., O'Brien, W. L., & King, G. A. (2000). Validity of four motion sensors in measuring moderate intensity physical activity. Medicine & Science in Sports & Exercise, 32(9, Suppl.), 471-480.
Go to original source... - Beets, M. W., Patton, M. M., & Edwards, S. (2005). The accuracy of pedometer steps and time spent during walking in children. Medicine & Science in Sports & Exercise, 37(3), 513-520.
Go to original source... - Brage, S., Brage, N., Wedderkopp, N., & Froberg, K. (2003). Reliability and validity of the computer science and applications accelerometer in a mechanical setting. Measurement in Physical Education and Exercise Science, 7(2), 101-119.
Go to original source... - Brage, S., Wedderkopp, N., Andersen, L. B., & Froberg, K. (2003). Influence of step frequency on movement intensity predictions with the CSA accelerometer: A field validation study in children. Pediatric Exercise Science, 15, 277-287.
Go to original source... - Brage, S., Wedderkopp, N., Franks, P. W., Andersen, L. B., & Froberg, K. (2003). Reexamination of validity and reliability of the CSA monitor in walking and running. Medicine & Science in Sports & Exercise, 35, 1447-1454.
Go to original source... - Brisson, T., & Tudor-Locke, C. (2004). The health benefits of physical activity and the role of step counters. Canadian Journal of Dietetic Practice and Research, 65(1), 26-29.
- Crouter, S. E., Schneider, P. L., Karabulut, M., & Bassett, D. R. (2003). Validity of 10 electronic pedometers for measuring steps, distance, and energy cost. Medicine & Science in Sports & Exercise, 35, 1455-1460.
Go to original source... - de Vries, S. I., Bakker, I., Hopman-Rock, M., Hirasing, R. A., & van Mechelen, W. (2006). Clinimetric review of motion sensors in children and adolescents. Journal of Clinical Epidemiology, 59, 670-680.
Go to original source...
Go to PubMed... - Eisenmann, J. C., Strath, S. J., Shadrick, D., Rigsby, P., Hirsch, N., & Jacobson, L. (2004). Validity of uniaxial accelerometry during activities of daily living in children. European Journal of Applied Physiology, 91, 259-263.
Go to original source...
Go to PubMed... - Ekelund, U., Sjöström, M., Yngve, A., Poortvliet, E., Nilsson, A., Froberg, K., Wedderkopp, N., & Westerterp, K. (2001). Physical activity assessed by activity monitor and doubly labeled water in children. Medicine & Science in Sports & Exercise, 33, 275-281.
Go to original source... - Hatano, Y. (1993). Use of the pedometer for promoting daily walking exercise. International Council for Health, Physical Education, and Recreation, 29, 4-8.
- Hendelman, D., Miller, K., Baggett, C., Debold, E., & Freedson, P. (2000). Validity of accelerometry for the assessment of moderate intensity physical activity in the field. Medicine & Science in Sports & Exercise, 32(9, Suppl.), 442-449.
Go to original source... - Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005). Comparison of two waist mounted and two ankle mounted electronic pedometers. European Journal of Applied Physiology, 95, 335-343.
Go to original source...
Go to PubMed... - Kelly, L. A., Reilly, J. J., Fairweather, S. C., Barrie, S., Grant, S., & Paton, J. Y. (2004). Comparison of two accelerometers for assessment of physical activity in preschool children. Pediatric Exercise Science, 16, 324-333.
Go to original source... - Kelly, L. A., Reilly, J. J., Grant, S., & Paton, J. Y. (2004). Objective measurement of physical activity in pre school children: Comparison of two accelerometers against direct observation [Abstract]. Medicine & Science in Sports & Exercise, 36(5, Suppl.), 329.
- King, G. A., Torres, N., Potter, C., Brooks, T. J., & Coleman, K. J. (2004). Comparison of activity monitors to estimate energy cost of treadmill exercise. Medicine & Science in Sports & Exercise, 36, 1244-1251.
Go to original source... - Le Masurier, G. C., Lee, S. M., & Tudor-Locke, C. (2004). Motion sensor accuracy under controlled and free living conditions. Medicine & Science in Sports & Exercise, 36(5), 905-910.
Go to original source... - Le Masurier, G. C., & Tudor-Locke, C. M. (2003). Comparison of pedometer and accelerometer accuracy under controlled conditions. Medicine & Science in Sports & Exercise, 35, 867-871.
Go to original source... - Melanson, E. L., & Freedson, P. S. (1995). Validity of Computer Science and Applications, Inc. (CSA) activity monitor. Medicine & Science in Sports & Exercise, 27, 934-940.
Go to original source... - Melanson, E. L., Knoll, J. R., Bell, M. L., Donahoo, W. T., Hill, J. O., Nysse, L. J., Lanningham-Foster, L., Peters, J. C., & Levine, J. A. (2004). Commercially available pedometers: Considerations for accurate step counting. Preventive Medicine, 39, 361-368.
Go to original source...
Go to PubMed... - Metcalf, B. S., Curnow, J. S. H., Evans, C., Voss, L. D., & Wilkin, T. J. (2002). Technical reliability of the CSA activity monitor: The early bird study. Medicine & Science in Sports & Exercise, 34, 1533-1537.
Go to original source... - Montoye, H. J., Kemper, H. C. G., Saris, W. H. M., & Washburn, R. A. (1996). Measuring physical activity and energy expenditure. Champaign, IL: Human Kinetics.
- Nichols, J. F., Morgan, C. G., Chabot, L. E., Sallis, J. F., & Calfas, K. J. (2000). Assessment of physical activity with the Computer Science and Applications, Inc., accelerometer: Laboratory versus field validation. Research Quarterly for Exercise and Sport, 71, 36-43.
Go to original source...
Go to PubMed... - Odom, L. R., & Morrow, J. R. (2006). What's this r? A correlational approach to explaining validity, reliability and objectivity coefficients. Measurement in Physical Education and Exercise Science, 10(2), 137-145.
Go to original source... - Plasqui, G., & Westerterp, K. R. (2007). Physical activity assessment with accelerometers: An evaluation against doubly labeled water. Obesity, 15, 2371-2379.
Go to original source...
Go to PubMed... - Puyau, M. R., Adolph, A. L., Vohra, F. A., & Butte, N. F. (2002). Validation and calibration of physical activity monitors in children. Obesity Research, 10(3), 150-157.
Go to original source...
Go to PubMed... - Rowlands, A. V., Stone, M. R., & Eston, R. G. (2007). Influence of speed and step frequency during walking and running on motion sensor output. Medicine & Science in Sports & Exercise, 39(4), 716-727.
Go to original source... - Sirard, J. R., Melanson, E. L., Li, L., & Freedson, P. S. (2000). Field evaluation of Computer Science and Applications, Inc. physical activity monitor. Medicine & Science in Sports & Exercise, 32, 695-700.
Go to original source... - Sirard, J. R., & Pate, R. R. (2001). Physical activity assessment in children and adolescents. Sports Medicine, 31(6), 439-454.
Go to original source...
Go to PubMed... - Schneider, P. L., Crouter, S. E., & Bassett, D. R. (2004). Pedometer measures of free living physical activity: Comparison of 13 models. Medicine & Science in Sports & Exercise, 36, 331-335.
Go to original source... - Schneider, P. L., Crouter, S. E., Lukajic, O., & Bassett, D. R. (2003). Accuracy and reliability of 10 pedometers for measuring steps over a 400 m walk. Medicine & Science in Sports & Exercise, 35, 1779-1784.
Go to original source... - Strath, S. J., Bassett, D. R., & Swartz, A. M. (2003). Comparison of MTI accelerometer cut-points for predicting time spent in physical activity. International Journal of Sports Medicine, 24(4), 298-303.
Go to original source...
Go to PubMed... - Swartz, A. M., Strath, S. J., Bassett, D. R., O'Brien, W. L., King, G. A., & Ainsworth, B. E. (2000). Estimation of energy expenditure using CSA accelerometers at hip and wrist sites. Medicine & Science in Sports & Exercise, 32(Suppl., 9), 450-456.
Go to original source... - The ActiGraph. (2007). ActiTrainer users manual. Pensacola, FL: The ActiGraph.
- Trost, S. G., Ward, D. S., Moorehead, S. M., Watson, P. D., Riner, W., & Burke, J. R. (1998). Validity of the Computer Science and Applications (CSA) activity monitor in children. Medicine & Science in Sports & Exercise, 30, 629-633.
Go to original source... - Tudor-Locke, C., Ainsworth, B. E., Thompson, R. W., & Matthews, C. E. (2002). Comparison of pedometer and accelerometer measures of free living physical activity. Medicine & Science in Sports & Exercise, 34(12), 2045-2051.
Go to original source... - Tudor-Locke, C., & Bassett, D. R. (2004). How many steps/day are enough? Preliminary pedometer indices for public health. Sports Medicine, 34, 1-8.
Go to original source...
Go to PubMed... - van Coevering, P., Harnack, L., Schmitz, K., Fulton, J. E., Galuska, D. A., & Gao, S. (2005). Feasibility of using accelerometers to measure physical activity in young adolescents. Medicine & Science in Sports & Exercise, 37, 867-871.
Go to original source... - Vincent, S. D., & Sidman, C. L. (2003). Determining measurement error in digital pedometers. Measurement in Physical Education and Exercise Science, 7(1), 19-24.
Go to original source... - Welk, G. J., Blair, S. N., Wood, K., Jones, S., & Thompson, R. W. (2000). A comparative evaluation of three accelerometry based physical activity monitors. Medicine & Science in Sports & Exercise, 32(9, Suppl.), 489-497.
Go to original source... - Welk, G. J., Schnaben, J. A., & Morrow, J. R. (2004). Reliability of accelerometry based activity monitors: A generalizability study. Medicine & Science in Sports & Exercise, 36, 1637-1645.
Go to PubMed... - Welk, G. J., Differding, J. A., Thompson, R. W., Blair, S. N., Dziura, J., & Hart, P. (2000). The utility of the digi walker step counter to assess daily physical activity patterns. Medicine & Science in Sports & Exercise, 32(9, Suppl.), 481-488.
Go to original source... - Yngve, A., Nilsson, A., Sjöström, M., & Ekelund, U. (2003). Effect of monitor placement and of activity setting on the MTI accelerometer output. Medicine & Science in Sports & Exercise, 35, 320-326.
Go to original source...
This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.